📖 This is a static documentation page. Open the interactive version with live canvas demos →

Record the oven and the gauge

What an operation is done with is written on the tab "Equipment" of the passport. For reflow it is the oven and the instrument that takes its temperature profile.

On the canvas

The operation "Reflow" with one step. The panels are closed; their buttons are at the top of the canvas.

Steps

  1. Right-click the operation "Reflow", point at "Passport tab" and choose "Equipment". The list is empty: "No equipment".
  2. Press "+ Add" and choose "Equipment / machine" in the list of kinds that opens. A row with the letter M appears in the list, and its fields open on the right.
  3. Type OV-8 into the field "PN" and press Enter. The part number appears in the row.
  4. Press "+ Add" again and choose "Measuring instrument". A second row appears, with the letter G.

Check

The list has two rows: M, OV-8, 1 pcs and G, 1 pcs. At the bottom of the window — "Equipment: 2".

If it did not work

The rule

The fields on the right depend on the kind. A machine has the section "Infrastructure": area, power, connections. Lower comes the section "Verification / calibration / test" — it is filled in for a measuring instrument.